  1. Calibration Management
  2. Data Model
Reference

The tables behind Calibration Management

Calibration Management ships with 24 tables, grouped here by the feature that uses them. Every record your team works with lives in one of them, and you can add fields and tables in Proto.

Tables
24
Features
7
Change it
Add fields and tables in Proto

Every table, by feature

Instrument Register

4 tablesAbout this feature
  • Instruments

    The accountable physical instrument and its current service state.

    Linked to Locations, Users
  • Instrument ranges

    Declared measurands and usable ranges of an instrument.

    Linked to Instruments
  • Locations

    Sites, laboratories and controlled storage areas.

  • Users

    Authorized people, identity mapping and operating scope.

    Linked to Locations

Calibration Planning

5 tablesAbout this feature
  • Calibration plans

    Versioned calibration obligations for each instrument.

    Linked to Instruments, Calibration methods, Decision rules, Service providers
  • Calibration methods

    Versioned methods and qualification prerequisites.

    Linked to Users
  • Method points

    Required calibration points and evidence requirements in one method revision.

    Linked to Calibration methods
  • Decision rules

    Versioned, technically approved rules for result evaluation.

    Linked to Users
  • Interval reviews

    Evidence and decisions for changing future calibration cadence.

    Linked to Calibration plans, Users

Calibration Execution

3 tablesAbout this feature
  • Calibration orders

    A scheduled internal job or external calibration request.

    Linked to Instruments, Calibration plans, Service providers, Users
  • Measurement results

    Original and subsequent observations at a method point.

    Linked to Calibration orders, Method points, Users
  • Environmental readings

    Method-relevant conditions observed during the job.

    Linked to Calibration orders

Standards and Traceability

3 tablesAbout this feature
  • Reference standards

    Reference artifacts and their supporting calibration evidence.

    Linked to Users
  • Order standards

    The reference evidence actually used for a calibration.

    Linked to Calibration orders, Reference standards, Users
  • Service providers

    External laboratories and reviewed service boundaries.

    Linked to Users

Certificate Review

1 tableAbout this feature
  • Certificates

    Versioned issued or received calibration evidence and internal acceptance.

    Linked to Calibration orders, Service providers, Users

Impact and Hold Control

5 tablesAbout this feature
  • Impact assessments

    The Quality Manager decision on historical use at risk.

    Linked to Instruments, Calibration orders, Users
  • Affected uses

    Each candidate historical use and its reviewed disposition.

    Linked to Impact assessments, Instrument use records
  • Hold records

    Restrictions that prevent use until their own release requirements are met.

    Linked to Instruments, Calibration orders, Users
  • Release requests

    Independent return-to-service decisions for an individual hold.

    Linked to Instruments, Hold records, Certificates, Impact assessments
  • Corrective actions

    Work needed to resolve an instrument or assessment finding.

    Linked to Instruments, Impact assessments, Users

Operations and Evidence

3 tablesAbout this feature
  • Instrument use records

    Recorded measurement use with links to the owning business system.

    Linked to Instruments, Users, Instrument ranges
  • Integration events

    Reconciliation of configured imports and external handoffs.

  • Audit events

    Append-only decision and change evidence.

    Linked to Users

Keys and references

Instrument number identifies the physical asset across its life. Serial numbers support reconciliation but do not replace that identity. Method, rule, plan and certificate revisions retain exact historical references. Source-system and event-key pairs make imports repeatable; a different payload using an existing key is a conflict.

Approved evidence and submitted observations are immutable. Corrections append linked versions with a reason. Retire or supersede referenced records instead of deleting the history needed to explain a decision. Every reference must resolve within the same tenant, and instrument ranges must belong to the instrument being used.

Migration order

  1. Reconcile Users and Locations, then instrument identities and custody.
  2. Import reviewed ranges, methods, points, decision rules, providers and reference evidence.
  3. Establish approved plans without rewriting historical due-date obligations.
  4. Import calibration jobs, observations and certificates with their original versions and dates.
  5. Reconcile use events, holds and open impact or corrective work.
  6. Verify permissions, independent decisions and integration replay before daily use.

Set up Calibration Management your way.

Start free, then use Proto to change fields, steps and approvals before your team goes live.

How to get started

A personal agent for your business

Get started with Proto

Your app is selected. Download Proto, then open it with this context.

Selected appCalibration Management

Choose your computer’s platform.

Download Proto

Install Proto, then return to this panel.

Already installed? Open Proto

Free to use. Your own model provider may charge for usage.