Feature · Calibration Execution

Calibration Execution

Capture as-found and as-left measurements without losing the original observations.

OverviewMy Calibration Work
Calibration Management · Calibration Execution

My Calibration Work

Calibration orders

New
Order numberInstrumentStart dateEnd dateStatus
CO-31060Flow meter, water loop09 Nov16 NovDraft
CO-20699Analytical balance, lab bench 423 Nov01 DecScheduled
CO-67096Temperature probe, cold room17 Nov21 NovIn progress
CO-36457Analytical balance, lab bench 423 Nov26 NovSubmitted
CO-12671Pressure gauge, mixing line 220 Nov25 NovReviewed
6 of 6 records
Flow meter, water loopCalibration orders · CO-31060
Draft
Start date09 Nov
End date16 Nov
Example screen with sample data

What you can do

Preserve the condition that arrived

The execution workspace starts with the identified instrument and the method revision attached to its calibration order. The Calibration Technician records condition on receipt, required reference standards and the measurement environment. Starting the job raises a calibration hold so the instrument cannot appear available while its condition is being evaluated.

As-found observations describe the instrument before adjustment. They remain separate from as-left observations recorded after adjustment or repair. A later satisfactory result must not replace the evidence that prompted an investigation. Adjustment details explain what changed between those phases and allow the reviewer to understand why another measurement set was required.

Capture the measurement with its context

Each result identifies the method point, measured phase, observation time, reference value, instrument indication and unit. The record also includes expanded uncertainty, coverage factor and supporting evaluation evidence. These are method-specific technical inputs; the application must not fill them with invented defaults to make a form appear complete.

  • Require method points belonging to the order’s frozen method revision.
  • Keep reference and indicated values in compatible declared units.
  • Retain original observations when a transcription needs correction.
  • Record the person and time responsible for each measurement.
  • Make missing coverage or unresolved evaluation visible to the reviewer.

Environmental readings capture the conditions required by the method, with a source log when available. The system records whether those conditions meet the method requirements. It does not prescribe temperature limits, stabilization times or a physical measurement technique for every instrument family.

Apply the approved decision rule

A tolerance comparison alone is not a substitute for the agreed decision rule. Calibration plans selects the exact decision rules revision used to evaluate the result. That revision explains acceptance boundaries, uncertainty treatment and borderline outcomes. Reviewed manual evaluation remains available where there is no validated calculation implementation.

If automatic evaluation is configured, its implementation and test evidence must match the approved rule. Until then, results remain not evaluated. Failed, indeterminate or incomplete evidence cannot be converted into a passing result by a technician changing a summary field. Measurement Review exposes those states for technical evaluation.

Submit a stable evidence set

Once the technician submits the job, its measurement set becomes immutable. A correction appends a linked observation with a reason and preserves the original. The reviewer should be able to determine which observation was superseded, who made the correction and whether the certificate also needs a new revision.

An external laboratory may provide a certificate without every raw observation. The coordinator records that limitation against the agreed evidence requirements and sends it for review. Missing data must remain missing until obtained; it must never be reconstructed from a rounded summary or copied from another instrument’s job. Acceptance depends on the provider contract and technical review, not on the upload succeeding.

What it keeps track of

Data model
Calibration orders
A scheduled internal job or external calibration request.
Measurement results
Original and subsequent observations at a method point.
Environmental readings
Method-relevant conditions observed during the job.

Who uses it

Permissions
Calibration Technician
Records assigned work.
Metrology Reviewer
Assesses evidence independently.
Calibration Coordinator
Manages external submissions and scheduling exceptions.
Admin
Configures access without changing technical results.

Set up Calibration Management your way.

Start free, then use Proto to change fields, steps and approvals before your team goes live.

How to get started

A personal agent for your business

Get started with Proto

Your app is selected. Download Proto, then open it with this context.

Selected appCalibration Management

Choose your computer’s platform.

Download Proto

Install Proto, then return to this panel.

Already installed? Open Proto

Free to use. Your own model provider may charge for usage.