Feature · Inspection execution

Inspection execution

Inspection execution is where a planned check becomes observed evidence. The Inspector / QC Operator opens an assigned inspection, records measurements against specifications and cites defect codes when the inspected material fails. Quality Manager can review the outcome and related nonconformance.

OverviewCalibration Due Soon
Quality Management System · Inspection execution

Calibration Due Soon

Calibration records

New
Record numberEquipment IDEquipment nameNext calibration dueStatus
CR-84283EI-153Equipment 16307 OctActive
CR-98105EI-823Equipment 53514 OctOut for calibration
CR-28481EI-120Equipment 82503 OctOut of tolerance
CR-21721EI-470Equipment 51011 OctRetired
CR-31363EI-708Equipment 42218 OctActive
6 of 6 records
EI-153Calibration records · CR-84283
Active
Equipment nameEquipment 163
Next calibration due07 Oct
Example screen with sample data

What you can do

Keep the result tied to its source

An inspection identifies the item, stage, inspection date, source and source reference. Lot and serial numbers can narrow the affected material. Its sample, accept and reject numbers give the inspector a basis for the decision. The inspector records each measured value or text observation against a specification. Pass, fail and marginal result values keep the parameter-level evidence separate from the inspection’s overall outcome.

Defect instances give each observed defect a code, quantity, location and notes. The defect catalog carries severity and category. A failed or conditional inspection triggers a nonconformance report once, and its worst cited defect severity influences the new report. This lets the quality team move from an individual measurement to a controlled issue without losing the source inspection.

The Inspections feature page provides a filtered worklist, inspections by type and record detail. It opens native record forms for edits. An inspector can use it to find a lot, review its stage and open the full record for results. The record’s calibration reference also matters: when equipment is marked out of tolerance, inspections using it on or after the last calibration date are flagged for review.

How the work is organized

  • Assigned queue. The inspector starts from work tied to their user record.
  • Measurement evidence. Individual results preserve the specification and observed value.
  • Defect evidence. Defect instances identify the code and quantity behind a failed outcome.

What to agree during setup

Agree how source references are entered, which inspection type applies to each stage and when a conditional outcome is appropriate. Inspectors should know who reviews the overall disposition. Quality Manager should decide the review procedure for a calibration flag, including how to locate other inspections that used the same instrument.

Check the handoff on an actual case

Open an incoming inspection for a component lot. Record a measured dimension and mark its parameter result. Add a defect instance with quantity and a catalog code. Move the inspection to Fail. Check that a single linked nonconformance report appears with the expected affected item and severity. Revisit the inspection without creating a duplicate report. Then mark its referenced calibration record out of tolerance and check that the inspection is flagged if its date falls in the affected period.

What your team sees

  • Open Inspections — Active work showing the item, stage and assigned inspector.
  • Failed Inspection Board — Failed and conditional outcomes grouped by status for review.
  • My Inspection Worklist — The inspector’s own queue before measurement.

Follow the work through

What it keeps track of

Data model
Inspections
Inspection event header with status and rolled-up pass/fail outcome.
Inspection results
Per-specification measurement recorded during an inspection.
Defect instances
Per-defect-code occurrences found in an inspection.
Defects
Defect catalog with severity and category cited by defect instances and NCR defects.
Specifications
Per-item specification sheet, one row per item per spec parameter.
Calibration records
Calibration log for measurement equipment used in inspections.
Non conformance reports
Non conformance report header driving containment, disposition and CAPA.

Who uses it

Permissions
Inspector / QC Operator
Records measurements and defects.
Quality Manager
Reviews outcomes.
Quality Engineer
Maintains the measurement basis.