Connects to the tools you use
Set up connections through ERP.AI and Proto workflows, with every change logged.
- Calibration Management
- Inspection and test records
- Instrument availability
- Laboratory documents
- Quality case handoff
Keep instrument identity, calibration schedules and measurement evidence together. Calibration Management gives metrology and quality teams a shared record of what is due, what was measured, who reviewed the evidence and which restrictions remain open.
Calibration orders in one list
An independent Metrology Reviewer approves the proposed technical plan and interval.
Every feature works on the same records. Pick one to see the screen your team works in.
Identify each instrument, range, custodian and permitted use.
Instruments
Schedule approved methods and maintain evidence for interval changes.
Approval waits for the metrology reviewer
| Review number | Plan | Proposed days | Prepared by | Submitted date | Status | |
|---|---|---|---|---|---|---|
| IR-60267 | Mixing line pressure gauge plan | 8 | Olivia Hart | 31 Oct | Submitted | |
| IR-33863 | Lab balance quarterly plan | 25 | Mei Chen | 21 Oct | Submitted | |
| IR-19795 | Cold room probe plan | 10 | Kwame Mensah | 19 Oct | Submitted | |
| IR-79804 | Storage humidity logger plan | 7 | Daniel Ruiz | 04 Nov | Submitted | |
| IR-40992 | Cold room probe plan | 12 | Iris Nakamura | 26 Oct | Submitted |
Capture as-found and as-left measurements without losing the original observations.
Calibration orders
| Order number | Instrument | Start date | End date | Status | |
|---|---|---|---|---|---|
| CO-31060 | Flow meter, water loop | 15 Oct | 22 Oct | Draft | |
| CO-20699 | Analytical balance, lab bench 4 | 29 Oct | 06 Nov | Scheduled | |
| CO-67096 | Temperature probe, cold room | 23 Oct | 27 Oct | In progress | |
| CO-36457 | Analytical balance, lab bench 4 | 29 Oct | 01 Nov | Submitted | |
| CO-12671 | Pressure gauge, mixing line 2 | 26 Oct | 31 Oct | Reviewed |
Link reference standards, certificate evidence and measurement conditions.
Reference standards
Review results and preserve issued certificate revisions.
Review calibration evidence waits for the metrology reviewer
| Certificate number | Order | Issued date | Result summary | Prepared by | Status | |
|---|---|---|---|---|---|---|
| CRT-85435 | Pressure gauge annual calibration | 20 Oct | Pass | Daniel Ruiz | Submitted | |
| CRT-87758 | Flow meter field calibration | 11 Oct | Fail | Elena Petrova | Submitted | |
| CRT-88904 | Pressure gauge annual calibration | 13 Oct | Indeterminate | Kwame Mensah | Submitted | |
| CRT-37005 | Torque wrench six-month calibration | 11 Oct | Pass | Elena Petrova | Submitted | |
| CRT-62260 | Temperature probe verification | 10 Oct | Fail | Kwame Mensah | Submitted |
Assess affected use and require an independent return-to-service decision.
Review historical impact waits for the quality manager
| Assessment number | Instrument | Window start | Window end | Use history complete | Prepared by | |
|---|---|---|---|---|---|---|
| IA-50348 | Torque wrench, assembly bay 3 | 29 Oct | 06 Nov | Yusuf Demir | ||
| IA-60949 | Temperature probe, cold room | 31 Oct | 08 Nov | Arun Mehta | ||
| IA-63690 | Analytical balance, lab bench 4 | 27 Oct | 01 Nov | Kwame Mensah | ||
| IA-52956 | Pipette, microbiology bench 2 | 31 Oct | 05 Nov | Iris Nakamura | ||
| IA-31433 | Digital multimeter, electrical lab | 04 Nov | 09 Nov | Elena Petrova |
Reconcile instrument use, supplier work and evidence exports.
Integration events
Instrument to approved use ships ready to use. 4 steps need a named approval before the work moves on: Approve plan (Metrology Reviewer), Review certificate (Metrology Reviewer), Resolve impact (Quality Manager) and Release for use (Quality Manager).
Identify the instrument, its measurement range and accountable custodian.
Review the method, decision rule and interval before scheduling controlled work.
Preserve observations, reference evidence and conditions before and after adjustment.
Independently check the calibration report and its supporting evidence.
Assess earlier use and document the treatment of uncertain or affected work.
Resolve the specific hold only when current evidence supports return to service.
Open any calibration order to see its measurement results, the roles that work on it, its process stages and its approvals on one page.
Assigned to, Start date and End date.
Each line is linked to this calibration order.
Calibration Coordinator, Calibration Technician and Metrology Reviewer, each with their own permissions.
Schedule and receive and Review certificate, with the role that acts.
Approve plan and Review certificate, with who decides.
Scheduled
| Order | Point | Phase |
|---|---|---|
| Voltage meter bench calibration | Torque at 50 Nm | As found |
| Pressure gauge annual calibration | Pressure at 5 bar | As left |
| Torque wrench six-month calibration | Temperature at 0 C | As found |
Signed in as Metrology Reviewer
| Decision | Approver | |
|---|---|---|
| Approve planReview the method, decision rule and interval before scheduling controlled work. | Metrology Reviewer | |
| Review certificateIndependently check the calibration report and its supporting evidence. | Metrology Reviewer | |
| Resolve impactAssess earlier use and document the treatment of uncertain or affected work. | Quality Manager | |
| Release for useResolve the specific hold only when current evidence supports return to service. | Quality Manager | |
| Approve calibration methods, decision rules, calibration plans, Certificates, interval reviews | Metrology Reviewer | |
| Review service providers | Metrology Reviewer |
Everyone opens Calibration Management to the work that is theirs. Pick a role to see what it starts with.
Owns the instrument register, due queue and external laboratory coordination within assigned locations.
This is the first screen this role sees.
Calibration orders · Calibration Coordinator
Performs assigned calibration work and records observations without approving their own technical evidence.
This is the first screen this role sees.
Calibration orders · Calibration Technician
Owns technical approval of methods, rules, plans, reference evidence and certificates independent of preparation.
This is the first screen this role sees.
Certificates · Metrology Reviewer
| Certificate number | Order | Issued date | Result summary | Prepared by | Status | |
|---|---|---|---|---|---|---|
| CRT-85435 | Pressure gauge annual calibration | 20 Oct | Pass | Daniel Ruiz | Submitted | |
| CRT-87758 | Flow meter field calibration | 11 Oct | Fail | Elena Petrova | Submitted | |
| CRT-88904 | Pressure gauge annual calibration | 13 Oct | Indeterminate | Kwame Mensah | Submitted | |
| CRT-37005 | Torque wrench six-month calibration | 11 Oct | Pass | Elena Petrova | Submitted | |
| CRT-62260 | Temperature probe verification | 10 Oct | Fail | Kwame Mensah | Submitted |
Owns historical impact decisions, corrective-action verification and release from hold independent of request preparation.
This is the first screen this role sees.
Impact assessments · Quality Manager
| Assessment number | Instrument | Window start | Window end | Use history complete | Prepared by | |
|---|---|---|---|---|---|---|
| IA-50348 | Torque wrench, assembly bay 3 | 29 Oct | 06 Nov | Yusuf Demir | ||
| IA-60949 | Temperature probe, cold room | 31 Oct | 08 Nov | Arun Mehta | ||
| IA-63690 | Analytical balance, lab bench 4 | 27 Oct | 01 Nov | Kwame Mensah | ||
| IA-52956 | Pipette, microbiology bench 2 | 31 Oct | 05 Nov | Iris Nakamura | ||
| IA-31433 | Digital multimeter, electrical lab | 04 Nov | 09 Nov | Elena Petrova |
Records assigned instruments' location, use and condition, and raises restrictions when suitability is uncertain.
This is the first screen this role sees.
Hold records · Instrument Custodian
Reads controlled evidence within the assigned scope without altering operational records or decisions.
This is the first screen this role sees.
Certificates · Auditor
| Certificate number | Order | Issued date | Result summary | Prepared by | Status | |
|---|---|---|---|---|---|---|
| CRT-85435 | Pressure gauge annual calibration | 20 Oct | Pass | Daniel Ruiz | Submitted | |
| CRT-87758 | Flow meter field calibration | 11 Oct | Fail | Elena Petrova | Submitted | |
| CRT-88904 | Pressure gauge annual calibration | 13 Oct | Indeterminate | Kwame Mensah | Submitted | |
| CRT-37005 | Torque wrench six-month calibration | 11 Oct | Pass | Elena Petrova | Submitted | |
| CRT-62260 | Temperature probe verification | 10 Oct | Fail | Kwame Mensah | Submitted |
Maintains identity, tenant configuration and configured connectors without bypassing technical or quality decisions. Scope checks apply on the server to reads, writes, files and exports. A person cannot approve an item they prepared, performed or requested, even after a role change or when holding additional authority. Independent approver eligibility is evaluated against authenticated identity and immutable provenance. Quality Managers may prepare assessments but a different eligible Quality Manager must approve them. Emergency action can add a hold; no emergency role bypass releases an instrument.
Operational reports that retain measurement context and unresolved exceptions.
This quarter
How far records got this quarter
| Stage | Reached | Step | |
|---|---|---|---|
| Draft | 39 | ||
| Scheduled | 20 | 51% | |
| In progress | 14 | 70% | |
| Submitted | 8 | 57% |
Sample counts per stage
Review current obligations by location and criticality, including overdue instruments and unresolved holds.
Compare like points and units while retaining method changes and uncertainty context.
Find submitted evidence awaiting a technical decision and rejected documents awaiting correction.
Locate dependent jobs when reference evidence needs investigation.
Review candidate uses, uncertain populations and external dispositions without labelling every candidate a confirmed defective product.
Explain which restriction was released, who authorized it and what remained unresolved.
Follow the evidence, effective date and plan revision behind each cadence change.
Compare incoming events with applied records and external acknowledgements.
See how Calibration Management fits your kind of team.
Each stage of instrument to approved use names the role that acts and the status it records, so a change is never anonymous.
Each stage, the role that acts and the status it records
Assistance for scheduling, evidence preparation and exception review within human authority.
Set up connections through ERP.AI and Proto workflows, with every change logged.
Every record lives in a table you can see, extend and export. Add fields or whole tables in Proto.
Browse all 24 tablesStart with one team and one process, then add the rest once the basics are running.
Identify the instrument fleet, locations, measurement ranges and responsible custodians. Technical owners supply approved methods, decision rules and uncertainty evidence.
Resolve duplicate identities and missing serials. Preserve historical status and distinguish missing evidence from an established passing result.
Assign preparation, technical review and quality release responsibilities. Test identity-based separation, tenant scope, file access and export authority through the API.
Schedule a real-shaped test case, retain as-found observations, submit a certificate and independently review it. Include a failure that triggers historical impact and a separate release request.
Exercise overdue date boundaries, stale approvals, concurrent holds, corrected certificates, duplicate imports and absent external acknowledgements.
$0per user
The base account and everyday work in the ERP.AI app are free, for every user.
| Usage | Per $1 |
|---|---|
| Record reads (list, filter, get) | 20,000 |
| Search or aggregate queries | 4,000 |
| Record writes | 4,000 |
| Imported or synced records | 200,000 |
| Workflow runs | 2,000 |
| AI agent runs | 2,000 |
| Scheduled jobs or webhooks | 20,000 |
| File uploads (MB) | 2,000 |
| CSV or PDF exports | 100 |
Click Get started, then use Proto to configure Calibration Management for your business. Bring the instrument register, approved methods, current certificates and named decision owners. Choose the first instrument group and configure the approval steps around the way your team works.
Follow an instrument from its approved method and due date through original measurements, certificate review and release history. When a result raises a concern, connect the investigation to earlier use records and the quality decisions that follow.
Certificate acceptance records the Metrology Reviewer's assessment of the evidence. A correctly reported failure can be accepted while the instrument remains held. Quality Manager release is a separate decision against the current evidence and every unresolved restriction.
Bring external laboratory certificates into the same review process as internal work. Keep the provider, service scope and original evidence together, with file or portal connections configured for your laboratory.
The coordinator proposes an interval with evidence, and the independent Metrology Reviewer approves it. There is no universal default claimed as a NIST requirement. Changes apply prospectively and retain previous obligations.
The instrument remains restricted and the quality team assesses potentially affected historical use. A later satisfactory result does not close that investigation by itself. Missing use history must receive explicit treatment.
Corrections append a linked record with a reason and preserve the original observation. Submitted evidence and accepted certificate files cannot be silently overwritten. A revised certificate may require dependent decisions to be reviewed again.
Your qualified reviewers select the applicable methods, assess measurement evidence and authorise release. Calibration Management keeps those decisions connected to their supporting records. Laboratory accreditation and regulatory obligations remain with your organisation and its service providers.
An assistant can prepare evidence for review. It cannot bypass the independent Quality Manager decision, make up missing evidence or use administrative access as approval authority.
The assessment identifies potentially affected use and records its disposition or escalation. Product withdrawal, customer notification and recall execution remain in the customer's authorized quality process. The calibration app tracks evidence and acknowledgements.
Start free, then use Proto to change fields, steps and approvals before your team goes live.